Samsung SCH-U410

Product Data

Product Name:Samsung SCH-U410
Distributor:Samsung Electronics
Manufacture Year:2011
Test Date/Location:2011-05-27/MI
Product Group:Electronics
Product Type:Cell Phone
Test Method:XRF
View Full Report: iPhone 5 Ranks Higher than Galaxy S III in New Study on Toxic Chemicals in Mobile Phones

Product Rating

Key:
HIGH
MED
LOW
4.2

Overall Level

3.7
3.8
4.0
3.8
4.1

IMPORTANT NOTE: HealthyStuff.org ratings do not provide a measure of health risk or chemical exposure associated with any individual product, or any individual element or related chemical. Follow this link to read more.

Components Tested 

Component Bromine Chlorine Mercury Lead Antimony Tin Arsenic Chromium Cobalt Copper Nickel Cadmium
Button3,18920,4465136632780103,0191,672199,369174,58129
Sample 1030601046013857011,2950
Sample 2027257293001,9022483293,85410
Sample 3219,50601026090000
Sample 43,1890513663117090,9941,087199,369171,6430
Sample 5001735592780103,0191,6723,283174,58129
Sample 6100000000009
Sample 7420,44601019070200
Case982,3741,734050910,0348070,6311,218635,370243,39438
Sample 117,59210031002296490
Sample 292,99200509294000000
Sample 3713,01600132500430700
Sample 4712,98700116480380800
Sample 51427101274803500013
Sample 6082,37400126938070,6315952,33643,7800
Sample 7001,734007808,7111,2184,79098,22738
Sample 8017,5930027410,03400222635,370243,3940
Sample 957,58800118550280300
Sample 1009,48400041000007
Circuit Board264,43831,1026873,6901,73655,1372801,55386,858794,257438,7640
Sample 15370282109019,237046886,8586,373438,7640
Sample 258,170003,690055,1372801,553277453,668231,3570
Sample 3264,43831,10202,443048,10004500325,098269,1850
Sample 42976,07324187018,37305294932,2136,6260
Sample 5106,607000051,81101,4979,734213,948434,0760
Sample 68,44200220006780794,25700
Sample 745,66763768720501610400598,120317,7150
Sample 818,65803267965109000237,138125,0250
Sample 914,068079141,73616,9389001,8124,0630
Other160,07251,1131901225,32998,6238178,7403,777682,45877,74228
Sample 1211,9370086190360507
Sample 20269007138000000
Sample 300288745570165,8285982,66845,6460
Sample 49791141622412001190000
Sample 523340351491,14601113960,241240
Sample 68251,113005,32998,6230003,17900
Sample 7160,07200002,996000682,45800
Sample 80001220688178,74004,04677,7420
Sample 9672,611190901339602353,77723464328
Processor1581,199285908,971470294510
Sample 1630282108,8384702300
Sample 2671,199285308,9711002100
Sample 315800203,2820002510
Sample 40010907700029440
Screen57,82668625116,0199,495671271699,0982430
Sample 1371822511357867102050
Sample 220122,6060000020
Sample 311,4162480081500271699,09800
Sample 457,8266860009,495021049,2122430
Sample 54649256,01900016000
Solder126,18100172086,391001,960571,77232,1110
Sample 1126,18100001,451000571,7728,2470
Sample 292,10700172086,391001,960416,30032,1110

Note: The above results are in parts per million (PPM) of a given chemical.
PPMs listed in bold face are the maximum detected value for a given chemical in all samples of a component.
You may click on a component to see all sample results.

Inline HTML

This content comes from a hidden element on this page.

The inline option preserves bound JavaScript events and changes, and it puts the content back where it came from when it is closed.

Click me, it will be preserved!

If you try to open a new ColorBox while it is already open, it will update itself with the new content.

Updating Content Example:
Click here to load new content