iPhone (original)

Product Data

Product Name:iPhone (original)
Distributor:Apple
Manufacture Year:2011
Test Date/Location:2011-05-27/MI
Product Group:Electronics
Product Type:Cell Phone
Test Method:XRF
View Full Report: iPhone 5 Ranks Higher than Galaxy S III in New Study on Toxic Chemicals in Mobile Phones

Product Rating

Key:
HIGH
MED
LOW
5.0

Overall Level

5.0
4.1
5.0
4.3
4.8

IMPORTANT NOTE: HealthyStuff.org ratings do not provide a measure of health risk or chemical exposure associated with any individual product, or any individual element or related chemical. Follow this link to read more.

Components Tested 

Component Bromine Chlorine Mercury Lead Antimony Tin Arsenic Chromium Cobalt Copper Nickel Cadmium
Button1,240157429496132782534,9905,6337
Sample 11157104961127852423157
Sample 21,240042901631502534,9905,6330
Case10,3392,934304893514921422,29048469,510519,16424
Sample 102,72500426501,599053,31560,8100
Sample 201,991140485821422,29048456117,29217
Sample 3481090266149054,592266811519,1640
Sample 402,93400684201,570058,41765,06324
Sample 510,339419009350003469,510011
Sample 650304847680143,3943261,89961,3280
Circuit Board196,70112,7243,0141147,36067,6743611,558681523,225506,13835
Sample 123801370021,293017019347,91696,9960
Sample 2196,701000021,10002170454,97580,0250
Sample 342,32103,01401,3160000327,678110,3190
Sample 48,24302,73039035,341056681523,225235,7700
Sample 534,5771,807008094804410461,967035
Sample 6138,8992,18900067,67406040396,1339460
Sample 73,021302381147,36027,6423612014,783530
Sample 8612,72400199659011,558335283,102506,1380
Sample 914,4342,346001,33927,2470309237191,6211,0800
Other7,1601682,550139317,2985399,4385,065617,860406,24211
Sample 1102432430305,065542110
Sample 211230293370000311
Sample 3516820012400023,49500
Sample 480161382125085,0392901,338406,2420
Sample 57,16002,5500017,2985366939617,860150,3280
Sample 60013207663099,4384291,16373,4350
Processor2,6191,415831231,00015,48905621,5755790
Sample 114010015,48904001800
Sample 22,6191,41583371,0005,47005621600
Sample 350012306,37404001,5755790
Screen151,3154,5517,0304703,88222,294203,964158,0634,152783,637314,765870
Sample 11,0304,5512,637421,4487,224105,43700000
Sample 21,9641,9634,877533,88222,294203,9640000870
Sample 316,8670542017710,9910294,004622,948172,7470
Sample 42,17504,26619501,83212543611395,705195,4750
Sample 5106,47207,0304701361693611,6841,79164,687314,7650
Sample 6151,3150001359802274,152783,6376600
Sample 750314801270158,0632632,04936,5500
Sample 8111,947970921178,350410500
Solder32,7981,8941488070,81101970127,514940
  Sample 1000000000000
Sample 232,7981,8941488070,81101970127,514940

Note: The above results are in parts per million (PPM) of a given chemical.
PPMs listed in bold face are the maximum detected value for a given chemical in all samples of a component.
You may click on a component to see all sample results.

Inline HTML

This content comes from a hidden element on this page.

The inline option preserves bound JavaScript events and changes, and it puts the content back where it came from when it is closed.

Click me, it will be preserved!

If you try to open a new ColorBox while it is already open, it will update itself with the new content.

Updating Content Example:
Click here to load new content